Constant temperature and stability; Widely used in all kinds of swimming pools and pools,energy saving and enviromental
Item No. | Net dimension (W X D X H ) | PKG dimension (W X D X H ) | Circulation pipe diameter (inlet,outlet) | N.W. KG | G.W KG | CBM (M3) | 20'GP/40'P | |||
CTR04200101 | 1580*910*1180mm | 1670*980*1400mm | G2" | 230 | 260 | 2.3 | 6/14 | |||
CTR04250101 | 1580*910*1380mm | 1670*980*1620mm | G2" | 400 | 440 | 2.65 | 6/14 | |||
Item No. | Power Supply | Rated Power | Rated Current | Heating Capacity ① | 建议泳池水量 (m3) |
Outlet water temperature | Ambient temperature | Noise | ||
CTR04200101 | 380V/50Hz/3 | 17kw | 29A | 80kw | 100 | 55℃ | -10~45℃ | ≤68dB(A) | ||
CTR04250101 | 380V/50Hz/3 | 20kw | 38A | 100kw | 125 | 55℃ | -10~45℃ | ≤68dB(A) |
►High Efficiency titanium pipe, fast heat absorption, fast heating, high working efficiency
►Compared with hot water equipment applicable to other energy sources, it saves 65 to 80 percent of operating costs
►The heating and insulation can be set freely according to the needs.The unit automatically realizes the functions of timing, temperature and water level.
►Pool constant temperature heating, titanium metal heat exchanger,resist chlorine ion erosion in water, durable and stable performance.
►Wifi intelligent remote monitoring, anytime and anywhere control of hot water.
►Fault self-test, easy maintenance, complete protection functions,To ensure safety. Electric drive, no emissions, no combustion, no explosion risk
Model | CTR04200101 (spray coating) |
CTR04250101 (spray coating) |
|||||
POWER SUPPLY | 380V/50Hz/3 | 380V/50Hz/3 | |||||
Recommended pool capacity(m3) | 100 | 125 | |||||
Air/water 24℃/26℃temperature |
Heating Capacity(kw) | 80 | 100 | ||||
Input Power(kw) | 17 | 20 | |||||
Current(A ) | 29 | 38 | |||||
COP | 4.7 | 5 | |||||
Air/water 15℃/26℃ temperature |
Heating Capacity(kw) | 71 | 90 | ||||
Input Power(kw) | 16.9 | 19.8 | |||||
Current(A ) | 28.4 | 36.6 | |||||
COP | 4.2 | 4.55 | |||||
Air/water 7℃/26℃temperature |
Heating Capacity(kw) | 60 | 77 | ||||
Input Power(kw) | 16.3 | 18.8 | |||||
Current(A ) | 26.9 | 33.6 | |||||
COP | 3.68 | 4.106 | |||||
Outlet water Maximum temperature | 55℃ | 55℃ | |||||
Noise | ≤65dB(A) | ≤68dB(A) | |||||
Circulating water flow | 40-50T/h | 50-60T/h | |||||
Water Pressure Drop | 30kpa | 35kpa | |||||
Refrigerant | R410a | R410a | |||||
Waterpipe diameter (inlet,outlet) | G3" | G3" | |||||
Net Dimension | 2000*1100*2100mm | 2050*1150*2200mm | |||||
PKG Dimension | 2000*1100*2100mm | 2050*1150*2200mm | |||||
N.W./G.W. | 600/630kg | 650/680kg | |||||
Waterproof Rate | IPX4 | IPX4 | |||||
Compressor | Copeland/Danfoss | Copeland/Danfoss | |||||
Ambient temperature | -10~45℃ | -10~45℃ | |||||
20G/40G FCL QTY | 5/12 | 5/12 |
How Can I Fix a Compressor When It Stops Working?
Possible Reasons:
1. Power supply has error;
2. Cable connecting is loose;
3. Compressor is overheating.
Solutions:
1. Check reason and solve;
2. Check loose and repair;
3. Check reason and repair.
How Can I Deal with a Compressor Running but Not Heating?
Possible Reasons:
1. There is no refrigerant at all;
2. Compressor damaged.
Solutions:
1. Check leakage and repair.
2. Change compressor.
What Should I Do if the Heat Pump Doesn't Run?
Possible Reasons:
1. Power supply cable is loose;
2. The fuse of power supply is fused.
What Should I Do If My Heat Pump's Heating Capacity Is Too Low?
dication of energy efficiency in products. A rating system of A to G is used to Possible Reasons:
1. Refrigerant is not enough;
2. Water system insulating is not good;
3. Air heat exchanger is dirty;
4. Water heat exchanger scaled.
Solutions:
1. Check leakage and repair and refill gas;
2. Improve the insulation;
3. Clean air heat exchanger;
4. Clean water heat exchanger.
How Do I Troubleshoot the Fan Motor?
Possible Reasons:
1. Fan blade fixing screws are loose;
2. Fan motor damaged;
3. Fan motor capacitance damaged.
Solutions:
1. Tight the screws;
2. Change fan motor;
3. Change the capacitance.