Swimming Pool Heat Pump

Swimming Pool heat pump

Constant temperature and stability; Widely used in all kinds of swimming pools and pools

contact us

Share:

Item No. Net dimension                          (W X D X H ) PKG dimension                                             (W X D X H ) Circulation pipe diameter (inlet,outlet) N.W.   KG          G.W              KG     CBM                        (M3) 20'GP/40'P
CTR04300101 2000*1100*2100mm 2050*1150*2200mm G2.5" 750 780 5.2 5/12
 CTR04400101 2380*1360*2400mm 2430*1410*2500mm DN65 1100 1130 8.6 4(40'HGP)
Item No. Power Supply Rated Power   Rated Current     Heating Capacity ① 建议泳池水量
(m3)
Outlet water temperature Ambient temperature  Noise
CTR04300101 380V/50Hz/3 25kw 43A 120kw 150 55℃ -10~45℃ ≤68dB(A)
 CTR04400101 380V/50Hz/3 34kw 58A 160kw 200 55℃ -10~45℃ ≤68dB(A)

一、Features
►High Efficiency titanium pipe, fast heat absorption, fast heating, high working efficiency
►Compared with hot water equipment applicable to other energy sources,                                                                            

it saves 65 to 80 percent of operating costs
►The heating and insulation can be set freely according to the needs.                                                                                                           

The unit automatically realizes the functions of timing, temperature and water level.
►Pool constant temperature heating, titanium metal heat exchanger,                                                                                        

resist chlorine ion erosion in water, durable and stable performance.
►Wifi intelligent remote monitoring, anytime and anywhere control of hot water.
►Fault self-test, easy maintenance, complete protection functions,                                                                                        

To ensure safety. Electric drive, no emissions, no combustion, no explosion risk

 

 

Model  CTR04300101
(spray coating)
CTR04400101
(spray coating)
POWER SUPPLY 380V/50Hz/3 380V/50Hz/3
Recommended pool capacity(m3) 150 200
            Air/water
24℃/26℃temperature
 
Heating Capacity(kw)   120 160
Input Power(kw)  25 34
Current(A ) 43 58
COP 4.8 4.71

            Air/water
15℃/26℃ temperature
 Heating Capacity(kw)   110 145
Input Power(kw)           23.8 32.1
Current(A ) 40.3 54.5
COP 4.62 4.52

Air/water
 7℃/26℃temperature
Heating Capacity(kw)  98 128
Input Power(kw)  23.1 30
Current(A ) 39.6 50
COP 4.24 4.27
Outlet water Maximum temperature 55℃ 55℃
Noise ≤68dB(A) ≤68dB(A)
Circulating water flow 60-70T/h 80-90T/h
Water Pressure Drop 40kpa 50kpa
Refrigerant R410a R410a
Waterpipe diameter (inlet,outlet) G2.5" DN65
Net Dimension 2000*1100*2100mm 2380*1360*2400mm
PKG Dimension 2050*1150*2200mm 2430*1410*2500mm
N.W./G.W. 750/780kg 1100/1130kg
Waterproof Rate  IPX4 IPX4
Compressor Copeland/Danfoss Copeland/Danfoss
Ambient temperature -10~45℃ -10~45℃
20G/40G FCL QTY 5/12 4(40HGP)

How Can I Fix a Compressor When It Stops Working?
Possible Reasons: 
1. Power supply has error;
2. Cable connecting is loose;
3. Compressor is overheating.
 
Solutions:
1. Check reason and solve;
2. Check loose and repair;
3. Check reason and repair.

How Can I Deal with a Compressor Running but Not Heating?
Possible Reasons: 
1. There is no refrigerant at all;
2. Compressor damaged.
 
Solutions: 
1. Check leakage and repair.
2. Change compressor.

What Should I Do if the Heat Pump Doesn't Run?
Possible Reasons:
1. Power supply cable is loose;
2. The fuse of power supply is fused. 

What Should I Do If My Heat Pump's Heating Capacity Is Too Low?
dication of energy efficiency in products. A rating system of A to G is used to Possible Reasons: 
1. Refrigerant is not enough;
2. Water system insulating is not good;
3. Air heat exchanger is dirty;
4. Water heat exchanger scaled.
Solutions: 
1. Check leakage and repair and refill gas;
2. Improve the insulation;
3. Clean air heat exchanger;
4. Clean water heat exchanger.

How Do I Troubleshoot the Fan Motor?
Possible Reasons: 
1. Fan blade fixing screws are loose;
2. Fan motor damaged;
3. Fan motor capacitance damaged.
Solutions: 
1. Tight the screws;
2. Change fan motor;
3. Change the capacitance.