Dehydrating heat pump

CTR01100101      

Model No:
CTR01100101            
CTR01150101    

Application scope: fruits and vegetables, agricultural products, medicinal materials, seafood, meat, etc

contact us

Share:

Item No. Net dimension  (W X D X H ) PKG dimension   (W X D X H ) Volume of drying room N.W.   KG          G.W       KG     CBM     (M3) 20'GP/40'GP/45GP
CTR01100101 1840*1945*1570 mm 1900*2000*1770mm   500 580 6.73 3/6/7
CTR01150101 1840*1945*1570 mm 1900*2000*1770mm   580 660 6.73 3/6/7
Item No. Power Supply Rated Power①   Rated Current     Heating Capacity ① Dehydration rate① COP Refrigerant Air outlet temperature Ambient temperature  Noise
CTR01100101 380V/50Hz/3 9.5kw 18A 22kw 35L/h 2.32 R134a 90℃ -10~45℃ ≤68dB(A)
CTR01150101 380V/50Hz/3 13kw 24.5A 30kw 52.5L/h 2.31 R134a 90℃ -10~45℃ ≤68dB(A)

1、All stainless steel sheet metal, noble appearance atmosphere, strong corrosion resistance, durable.
2、67% less electricity than traditional electric heating drying
3、Environmental protection insulation layer, reduce heat loss.
4、Add transverse fan for more even baking
5、Wifi intelligent remote monitoring, anytime and anywhere hold baking conditions
6、The use of environmental protection high temperature refrigerant, outlet temperature can reach 90℃
7、Drying products bright color, uniform drying, to ensure that food nutrition is not lost.

 

 

Application

Application scope: fruits and vegetables, agricultural products, medicinal materials, seafood, meat, etc

 

Model No. CTR01100101 CTR01150101
Power Supply 380V/50Hz/3 380V/50Hz/3
Drying room volume(L) 
 
Custom made Custom made
Ambient Temp(℃) -10~43 -10~43
Maximum temperature of the air outlet(℃) 90 90
Air out way  circulate circulate
refrigerant R134a R134a
Rated Power(kw)① 9.5 13
Maximum Power(kw) 19.5 26
Rated Current(A)①  18 24.5
Maximum Current(A)  29.7 39.5
Heating Capacity(kw) 22 30
COP 2.32 2.31
Dehydrating Ratio(L/h)①  35 52.5
Drying room design wind speed(m/s) 1.2 1.2
Electrical auxiliary thermal power(kw) 10 10
Comperrsor Copeland
IP Rating IPX4 IPX4
Running Noise ≤68dB(A) ≤68dB(A)
Rack sizes(mm) 810*605*30 810*605*30
Function Drying and dehumidification  Drying and dehumidification 
Control Panel 4-inch color screen, intelligent control 4-inch color screen, intelligent control
Temperature control precision of drying room(℃) ±1 ±1
Net Dimension 1840*1945*1570 mm 1840*1945*1570 mm
PKG Dimension 1900*2000*1770 mm 1900*2000*1770 mm
N.W./G.W. 500/580kg 580/660
20GP/40GP/45GP  FCL QTY 3/6/7 3/6/7
  ① Test condition: NBT 10156-2019, air outlet 70℃, ambient temperature 15/12℃

Heat pump Partnership FAQs

 

How Do I Sign Up?

To discuss new potential partnerships, please click here to fill out CTRE  partnership contact form. 

 

Will I Be Competing Against CTRE Direct Salespeople

No. The CTRE sales managers are incented to help you be successful. Any deals you win in their territory count towards their sales quota. We do not sell directly to end-users unless there are no CTRE partners in that market. And if our website receives some end-user inquiries, we normally send them over to our local partners, for FREE. 

 

How Long Is the Partnership Agreement?

The length of the agreement depends on the sales level. For example, channel partnership typically lasts for one year and renews automatically as long as the sales goal is achieved by your side.

 

Is There a Cost to Become a Heat Pump Partner?

You need to purchase a number of heat pump units to become our official OEM/ODM partners or CTRE resellers. For example, OEM/ODM partners are required to buy at least 10 customized units. 

 

Can I Apply to Become Your Heat Pump Partner?

Yes, we are currently looking for more OEM/ODM partners and CTRE resellers across the globe, who can distribute heat pump products in their local markets.

 

How Do I Participate in the Heat Pump Partner Program?

Once you contact us, we will get in touch with you to explain our products, company and service to see if it aligns with your business goals. Assuming it does, we will execute a partnership agreement and provide support with training, marketing materials, sales, implementation, and on-going customer support.

 

Heat Pump Troubleshooting FAQs

 

What Should I Do If My Heat Pump's Heating Capacity Is Too Low?

Possible Reason: 

Refrigerant is not enough;

2. Water system insulating is not good;

3. Air heat exchanger is dirty;

4. Water heat exchanger scaled.

Solution: 

1. Check leakage and repair and refill gas;

2. Improve the insulation;

3. Clean air heat exchanger;

4. Clean water heat exchanger.

 

How Do I Troubleshoot the Fan Motor?

Possible Reason: 

1. Fan blade fixing screw is loose;

2. Fan motor damaged;

3. Fan motor capacitance damaged.
 Solution: 

1. Tight the screw;

2. Change fan motor;

3. Change the capacitance.

 

Is There a Solution to a Noisy Compressor?

Possible Reason: 

  1. Expansion valve damaged lead to liquid entering compressor;

2. The internal parts of compressor damaged;

3. Compressor lack of oil.

Solution: 

1. Change expansion valve;

2. Change compressor;

3. Compensate oil for compressor.

How Can I Fix a Compressor When It Stops Working?

Possible Reason: 

1. Power supply has error;

2. Cable connecting is loose;

3. Compressor is overheating.

Solution:
1. Check reason and solve;

2. Check loose and repair;

3. Check reason and repair.

 

How Can I Deal with a Compressor Running but Not Heating?

Possible Reason: 

1. There is no refrigerant at all;

2. Compressor damaged.

Solution: 

1. Check leakage and repair.

2. Change compressor.

 

What Should I Do if the Heat Pump Doesn't Run?

Possible Reason:

1. Power supply cable is loose;

2. The fuse of power supply is fused. 

 Solution: 

1. Cut off the power supply to check and repair. 