Model No:
CTR02050101(spray coating)
CTR02060101(spray coating)
1.High efficiency and total heat solution:Heating+Cooling+Domestic hot water.
2.DC inverter technology to guarantee optimal operational reliability and efficiency.
3.Using R32 green refrigerant.
4.Brushless DC fan motors ensure the quiet operation;
5.Anti-freezing work in-25℃ degrees low temperature;
6.Adopted famous international brand inverter compressor;
7.Side discharge design;
8.Easy installation and easy maintenance
Model No. | Net dimension (W X D X H ) | PKG dimension (W X D X H ) | Circulation pipe diameter (inlet,outlet) | N.W. KG | G.W KG | CBM (M3) | 20'GP/40'GP | |||
CTR02050101 | 1020x450x1370mm | 1110x510x1510mm | G1.0" | 110 | 130 | 0.855 | 22/46 | |||
CTR02060101 | 1020x450x1370mm | 1110x510x1510mm | G1.0" | 115 | 135 | 0.855 | 22/46 | |||
Model No. | Power Supply | Rated Power | Rated Current | Heating Capacity ① | COP | Refrigerant | Outlet water temperature | Ambient temperature | Noise | |
CTR02050101 | 220V/50Hz/1 | 3.83kw | 16.65A | 11.1kw | 2.9 | R32 | 35℃ | -35~43℃ | ≤60dB(A) | |
CTR02050101 | 220V/50Hz/1 | 4.17kw | 18.13A | 12.1kw | 2.9 | R32 | 35℃ | -35~43℃ | ≤60dB(A) |
1.Mitsubishi DV Inverter Compressor
►Our DC Inverter Heat Pump uses the industry's best compressor,Mitsubishi DV inverter compressor The Mitsubishi DC inverter compressor uses EVI technology and automatically witches into heating or cooling working mode according to the ambient temperature.
2.Environmental friendly Refrigerant R32
►The R32 refrigerant is more environmentally friendly compared to other traditional refrigerants. lts ability to enable an inverter heat pump to recharge and recycle more effectively than some other refrigerants means that the unit can run at much higher efficiencies
3.DC inverter motor
►This DC motor runs at the exact speed it needs forthe optimal efficiency.In this way the DC heat pump averages 30% more efficiency versus a standard unit.
4.Ultra-silence fan blade
►With Mitsubishi rotary compressor and DC inverter brushless fans,our DC inverter heat pumps adopt new noise reduction measures so that the sound of the unit is controlled at a satisfactory level.
5.Italy Brand Carel Controller
►Our R32 DC inverter heat pumps are equipped with the intelligent CAREL controller,it is adopted to realize the linkage control between the heat pump unit and the terminal application end the system is easy to manipulate,stable in performance, and is truly a smart operating system.The WIFI APP enables users to operate their units through a smart phone wherever and whenever they are.
6.Expansion Tank
►Famous brand expansion tank can reducing electricity consumption and prolonging the service life of the pump
7.WiLo Circulating Pump
►The water circulation pump constant proper water flow rate,which will secure the heating performance andreduceaftersalesproblem.
8.High-end finned tube exchanger
►Super large surface ultra gold fin coil evaporator optimised for high heat transfer.
1.High efficiency and total heat solution:Heating+Cooling+Domestic hot water.
2.DC inverter technology to guarantee optimal operational reliability and efficiency.
3.Using R32 green refrigerant.
4.BrushlessDCfanmotorsecurequietoperation;
5.Anti-freezing work in-25℃ degrees low temperature;
6.Adopted famous international brand inverter compressor;
7.Side discharge design;
8.Easy installation and easy maintenance
Model No. | CTR02050101 | CTR02060101 | |||||
Power Supply | 220-240V/1PH/50Hz | 220-240V/1PH/50Hz | |||||
certified | ERP 35℃A+++/55℃A++ CE | ERP 35℃A+++/55℃A++ CE | |||||
Heating Air 7/6℃/ Water30-35℃ |
Heating Capacity(kw) | 7.95(7.5-18.5) | 8.3(7.8-19.5) | ||||
Power Input(kw) | 1.52(1.43-4) | 1.57(1.47-4.2) | |||||
Rated Current(A) | 6.61(6.2-17.5) | 6.83(6.35-18.3) | |||||
COP | 5.21(4.6-5.25) | 5.27(4.6-5.3) | |||||
Heating Air 7/6℃/ water 35-55℃ |
Heating Capacity(kw) | 6.83(6.6-15) | 7.13(6.95-17) | ||||
Power Input(kw) | 2.23(2.14-6.5) | 2.29(2.22-7.3) | |||||
Rated Current(A) | 9.7(9.3-28.3 | 9.96(9.6-32 | |||||
COP | 3.06(2.3-3.07 | 3.12(2.35-3.13 | |||||
Heating Air 35/26℃/water 12- 7℃ |
Cooling Capacity(kw) | 9(5.5-14.5) | 10(6-15.5) | ||||
Power Input(kw) | 3.59(1.7-6.3) | 3.97(1.85-6.7) | |||||
Rated Current(A) | 15.61(7.35-27.4) | 17.3(8-29.2 | |||||
COP | 2.51(2.3-3.2) | 2.52(2.31-3.23 | |||||
SCOP | Water outlet at 35℃ | 4.46 | 5.07 | ||||
Water outlet at 55℃ | 3.42 | 3.72 | |||||
Sound power Level | ≤60dB(A) | ≤60dB(A) | |||||
Sound power Level | Brand | Mits ubishi | |||||
Type | DC Inverter | ||||||
QTY | 1 | ||||||
Refrigerant | Type/QTY | R32 | |||||
Fan Motor | Fan Motor Type | Axial/DC Fan motor | |||||
Fan Motor QTY | 2 | ||||||
Air Flow(m3/h) | 4100-12000 | 4100-12000 | |||||
Evaporator | Ultra Gold Color Hydrophilic aluminium | ||||||
Throttling Devices | EEV | EEV | |||||
Water Condenser | Water/Refrigerant | Plate Type | Plate Type | ||||
Water flow rate(m3/h) | 1.7 | 2.1 | |||||
Water Pressure Drop(kPa) | 60 | 60 | |||||
Water flow Switch | Included as acces sories | Included as acces sories | |||||
Circulation Inlet/Outlet | 1 Inch | 1 Inch | |||||
Circulating pump | |||||||
Pipeline electric heating | |||||||
Expansion tank | |||||||
Aut omatic exhaust valve | |||||||
Outdoor air temperaturerange | Domestic Hot Water | -25~43℃ | -25~43℃ | ||||
Floor Heating | -25~35℃ | -25~35℃ | |||||
Cooling | -5~43℃ | -5~43℃ | |||||
Water outlet temperature range | Domestic Hot Water | 10~55℃ | 10~55℃ | ||||
Floor Heating | 10~55℃ | 10~55℃ | |||||
Cooling | 5~30℃ | 5~30℃ | |||||
Unit Dimension | mm | 1020x450x1370mm | 1020x450x1370mm | ||||
Pacling Dimension | mm | 1110x510x1510mm | 1110x510x1510mm | ||||
N.W/G.W | Kg | 115/135 | 115/135 | ||||
20GP/40HQ | Set | 22/46 | 22/46 | ||||
① Test conditions: dry bulb temperature -7±1℃, wet bulb temperature -8±1℃, influent temperature 30℃ heated to 35℃. |
To discuss new potential partnerships, please click here to fill out CTRE partnership contact form.
No. The CTRE sales managers are incented to help you be successful. Any deals you win in their territory count towards their sales quota. We do not sell directly to end-users unless there are no CTRE partners in that market. And if our website receives some end-user inquiries, we normally send them over to our local partners, for FREE.
The length of the agreement depends on the sales level. For example, channel partnership typically lasts for one year and renews automatically as long as the sales goal is achieved by your side.
You need to purchase a number of heat pump units to become our official OEM/ODM partners or CTRE resellers. For example, OEM/ODM partners are required to buy at least 10 customized units.
Yes, we are currently looking for more OEM/ODM partners and CTRE resellers across the globe, who can distribute heat pump products in their local markets.
Once you contact us, we will get in touch with you to explain our products, company and service to see if it aligns with your business goals. Assuming it does, we will execute a partnership agreement and provide support with training, marketing materials, sales, implementation, and on-going customer support.
Possible Reason:
Refrigerant is not enough;
2. Water system insulating is not good;
3. Air heat exchanger is dirty;
4. Water heat exchanger scaled.
Solution:
1. Check leakage and repair and refill gas;
2. Improve the insulation;
3. Clean air heat exchanger;
4. Clean water heat exchanger.
Possible Reason:
1. Fan blade fixing screw is loose;
2. Fan motor damaged;
3. Fan motor capacitance damaged.
Solution:
1. Tight the screw;
2. Change fan motor;
3. Change the capacitance.
Possible Reason:
2. The internal parts of compressor damaged;
3. Compressor lack of oil.
Solution:
1. Change expansion valve;
2. Change compressor;
3. Compensate oil for compressor.
How Can I Fix a Compressor When It Stops Working?
Possible Reason:
1. Power supply has error;
2. Cable connecting is loose;
3. Compressor is overheating.
Solution:
1. Check reason and solve;
2. Check loose and repair;
3. Check reason and repair.
Possible Reason:
1. There is no refrigerant at all;
2. Compressor damaged.
Solution:
1. Check leakage and repair.
2. Change compressor.
Possible Reason:
1. Power supply cable is loose;
2. The fuse of power supply is fused.
Solution:
1. Cut off the power supply to check and repair.
2. Change the fuse.